BASIC INFO
						
					
					
	RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Detector G01-0102-010
	RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S
	This portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S). The ToxiRAE 3’s high-performance, three-electrode sensor delivers the fastest possible response time. When used with the AutoRAE Lite bump test and calibration station, it provides a low total cost of ownership (TCO) to organizations that are looking to protect workers and deliver worksite CO and H2S personal detection compliance. With its water and dust-resistant housing, and three-alarm capability, it’s a valuable tool for ensuring workers are aware of the presence of CO or H2S.
	Key Features:
	Fully featured single-gas monitor
	0.1ppm resolution on Hydrogen Sulfide (H2S) sensor
	Carbon monoxide (CO) sensor
	Can record STEL, TWA, high and low alarms
	High-performance sensor for fastest possible response time
	Compatible with AutoRAE Lite bump test and calibration station
	Large, easy-to-read display
	Lightweight, easy to wear and use
	Logs up to 10 events
	Water- and dust-resistant
	Audible, visual, and vibration alarm
	Applications:
	Emergency Response
	Exploration
	Fracking
	Hazmat Response
	Plant Shutdown & Turn-Around
	Residential Calls
	Worker Exposure
	Specifications
	Detector Specifications
	Size 3.4" x 2.2" x 0.8" (8.6 cm x 5.5 cm x 2.0 cm)
	Weight 3.5 oz (99.4 g)
	Battery User-replaceable 2/3 AA high-capacity lithium
	Alarms:
	1) 95 dB typical (at 30 cm) buzzer and flashing red LED to indicate exceeded preset limits
	2) High: Displays “High” and emits 3 beeps and flashes per second
	3) Low: Displays “Low” and emits 2 beeps and flashes per second
	4) STEL: Displays “STEL” and emits 1 beep and flash per second
	5) TWA: Displays “TWA” and emits 1 beep and flash per second
	6) Vibration alarm
	7) 6-LED visible alarm
	Data logging 10 events
	Response time T90 < 12 seconds
	IP Rating IP-67
	EMI/RFI:
	Highly resistant to EMI/RFI.
	Compliant with EMC directive 2004/108/ECCertification 
	cCSAus: C1D1, Groups A, B, C, D, T4
	ATEX: II 1G Ex ia IIC T4 Ga
	IECEX: Ex ia IIC T4 Ga
	Operating Temperature:
	Continuous: -4° to 140° F (-20° to +60° C)
	Intermittent: -22° to 140° F (-30° to +60° C)Humidity 0 to 95% relative humidity (non-condensing)
	Warranty 2 years, including sensor and battery if used within specs
	Calibration Two-point calibration for zero and span
| Sensor Specifications | ||
| Gas | Gas Range (ppm) | Resolution (ppm) | 
| H2S | 0 to 100 | 0.1 | 
| CO | 0 to 500 | 1 | 
| CO | 0 to 1999 | 1 | 
	ToxiRAE 3 Ordering Options
	Pack of 1: 
	ToxiRAE 3 with specified sensor:
	2/3 AA lithium battery
	One mini-CD with instruction manual and training materials
	Alligator clip
	Calibration adapter
	Pack of 10:
	10 ToxiRAE 3 monitors with specified sensor
	2mini-CDswith instructionmanual and trainingmaterials
	2 calibration adapters
	10 alligator clips
	Pack of 100:
	10 packs of 10
	Accessories (optional)
	AutoRAE Lite Automatic Test and Calibration Station
	
	
		
| Ordering Information | |||
| Monitor | Pack of 1 | Pack of 10 | Pack of 100 | 
| H2S | G01-0102-000 | G01-0102-010 | G01-0102-100 | 
| 
					CO Low range  | 
				G01-0101-000 | G01-0101-010 | G01-0101-100 | 
| 
					CO High range  | 
				G01-0103-000 | G01-0103-010 | G01-0103-100 | 
| AutoRAE Lite | |||
| Bump Test and Calibration Station | T01-0100-000 | ||
			
           
		
	
							
											
											