BASIC INFO
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 1999PPM G01-0103-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Monitor G01-0102-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Detector G01-0102-010
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Detector G01-0101-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor G01-0101-010
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 500 PPM G01-0101-100
This portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S). The ToxiRAE 3’s high-performance, three-electrode sensor delivers the fastest possible response time. When used with the AutoRAE Lite bump test and calibration station, it provides a low total cost of ownership (TCO) to organizations that are looking to protect workers and deliver worksite CO and H2S personal detection compliance. With its water and dust-resistant housing, and three-alarm capability, it’s a valuable tool for ensuring workers are aware of the presence of CO or H2S.
Key Features:
Fully featured single-gas monitor
0.1ppm resolution on Hydrogen Sulfide (H2S) sensor
Carbon monoxide (CO) sensor
Can record STEL, TWA, high and low alarms
High-performance sensor for fastest possible response time
Compatible with AutoRAE Lite bump test and calibration station
Large, easy-to-read display
Lightweight, easy to wear and use
Logs up to 10 events
Water- and dust-resistant
Audible, visual, and vibration alarm
Applications:
Emergency Response
Exploration
Fracking
Hazmat Response
Plant Shutdown & Turn-Around
Residential Calls
Worker Exposure
Specifications
Detector Specifications
Size 3.4" x 2.2" x 0.8" (8.6 cm x 5.5 cm x 2.0 cm)
Weight 3.5 oz (99.4 g)
Battery User-replaceable 2/3 AA high-capacity lithium
Alarms:
1) 95 dB typical (at 30 cm) buzzer and flashing red LED to indicate exceeded preset limits
2) High: Displays “High” and emits 3 beeps and flashes per second
3) Low: Displays “Low” and emits 2 beeps and flashes per second
4) STEL: Displays “STEL” and emits 1 beep and flash per second
5) TWA: Displays “TWA” and emits 1 beep and flash per second
6) Vibration alarm
7) 6-LED visible alarm
Data logging 10 events
Response time T90 < 12 seconds
IP Rating IP-67
EMI/RFI:
Highly resistant to EMI/RFI.
Compliant with EMC directive 2004/108/ECCertification
cCSAus: C1D1, Groups A, B, C, D, T4
ATEX: II 1G Ex ia IIC T4 Ga
IECEX: Ex ia IIC T4 Ga
Operating Temperature:
Continuous: -4° to 140° F (-20° to +60° C)
Intermittent: -22° to 140° F (-30° to +60° C)Humidity 0 to 95% relative humidity (non-condensing)
Warranty 2 years, including sensor and battery if used within specs
Calibration Two-point calibration for zero and span
Sensor Specifications | ||
Gas | Gas Range (ppm) | Resolution (ppm) |
H2S | 0 to 100 | 0.1 |
CO | 0 to 500 | 1 |
CO | 0 to 1999 | 1 |
ToxiRAE 3 Ordering Options
Pack of 1:
ToxiRAE 3 with specified sensor:
2/3 AA lithium battery
One mini-CD with instruction manual and training materials
Alligator clip
Calibration adapter
Pack of 10:
10 ToxiRAE 3 monitors with specified sensor
2mini-CDswith instructionmanual and trainingmaterials
2 calibration adapters
10 alligator clips
Pack of 100:
10 packs of 10
Accessories (optional)
AutoRAE Lite Automatic Test and Calibration Station
Ordering Information | |||
Monitor | Pack of 1 | Pack of 10 | Pack of 100 |
H2S | G01-0102-000 | G01-0102-010 | G01-0102-100 |
CO Low range |
G01-0101-000 | G01-0101-010 | G01-0101-100 |
CO High range |
G01-0103-000 | G01-0103-010 | G01-0103-100 |
AutoRAE Lite | |||
Bump Test and Calibration Station | T01-0100-000 |