BASIC INFO
Yokogawa Pressure Transmitter Price EJA110E-JMS5J-912DB/D3/M01
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family of pressure transmitters. Released in 2012, it combines the ruggedness and success of the work-horse EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
The EJA110E is our standard traditional-mount differential pressure transmitter in this series.
EJA110E features include:
0.055% Accuracy (0.04% Accuracy optional)
0.1% Stability per 10 years
90 ms Response Time
Exida and TUV SIL 2 / SIL3 Certified
MWP 2,300 psi (MWP 3,600 psi option)
Local Parameter Setting (LPS)
EJA110E-JMS5J-912DB/D3/M01 | |
EJA110E | Differential pressure transmitter |
J | 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1 |
M | 1 to 100 kPa (4 to 400 inH2O) |
S | Refer to “Wetted Parts Material” Table |
5 | without process connector (1/4 NPT female on the cover flanges) |
J | B7 carbon steel |
9 | Horizontal piping and left side high pressure |
1 | Cast aluminum alloy |
2 | 1/2 NPT female, two electrical connections without blind plugs |
D | Digital indicator*8 |
B | 304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
/D3 | bar calibration (bar unit) |
/M01 | Cover flange |
*1: HART 5 or HART 7 is selectable. Specify upon ordering.
*2: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*3: Only applicable for Wetted parts material code S.
*4: Not applicable for measurement span code F.
*5: Not applicable for electrical connection code 0, 5, 7, 9 and A.
*6: Not applicable for electrical connection code 0, 5, 7 and 9.
*7: Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
*8: Not applicable for output signal code G.