BASIC INFO
Honeywell XNX-AMSV-RNIC1 XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V
XNX UNIVERSAL TRANSMITTER
XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies.
It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.
XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART? terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.
1. XNX Universal Transmitter- Flammable Standard Temperature with MPD sensor
1.1. INSTRUMENT
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL
XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL
XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V
XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL
XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V
1.2. SPARE MPD SENSORS
1.3. SPARE MPD REPLACEABLE CARTRIDGES
2. XNX Universal Transmitter- for use with Sensepoint HT or 705 HT Flammable Sensor
3. XNX Universal Transmitter- for use with XNX Toxic & Oxygen Sensors
4. XNX Universal Transmitter- for use with Optima Plus Or Searchline Excel Detectors
5. Searchline Excel kits with XNX Transmitters
6. XNX Universal Transmitter Accessories and Spare Parts
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL |
XNX-AMAV-NNCB1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-NHCB1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-RNCB1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-RHCB1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-MNCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-MHCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-FNCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-FHCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL |
XNX-AMSV-NNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-NHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-RNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-RHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-MNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-MHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-FNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. |
XNX-AMSV-FHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL |
XNX-AMAV-NNIF1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-NHIF1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-RNIF1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-RHIF1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-MNIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-MHIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-FNIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-AMAV-FHIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL |
XNX-AMSV-NNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR flammable (propane) sensor 0-100%LEL. |
XNX-AMSV-NHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-RNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-RHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-MNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-MHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-FNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. |
XNX-AMSV-FHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
XNX-AMAV-NNIV1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-NHIV1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-RNIV1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-RHIV1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-MNIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-MHIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-FNIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-AMAV-FHIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-NNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-NHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-RNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-RHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART ® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-MNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-MHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-AMSV-FNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. |
XNX-AMSV-FHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. |
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V. |
XNX-AMAV-NNIC1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-NHIC1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-RNIC1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-RHIC1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-MNIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-MHIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-FNIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-AMAV-FHIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v. |
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V. |
XNX-AMSV-NNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-NHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-RNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-RHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-MNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-MHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-FNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-AMSV-FHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL |
XNX-UTAV-NNCB1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-NHCB1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-RNCB1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-RHCB1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-MNCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-MHCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-FNCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-UTAV-FHCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL |
XNX-UTSV-NNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-NHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-RNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-RHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-MNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-MHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-FNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. |
XNX-UTSV-FHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL |
XNX-UTAV-NNIF1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-NHIF1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-RNIF1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-RHIF1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-MNIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-MHIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-FNIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX-UTAV-FHIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL |
XNX-UTSV-NNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-NHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-RNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-RHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-MNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-MHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX-UTSV-FNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. |
XNX -UTSV-FHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
XNX-UTAV-NNIV1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-NHIV1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-RNIV1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-RHIV1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-MNIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-MHIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-FNIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX-UTAV-FHIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-NNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-NHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-RNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-RHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART ® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-MNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-MHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
XNX-UTSV-FNIV1 XNX transmitter, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. |
XNX-UTSV-FHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. |
XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. |
XNX-UTAV-NNIC1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-NHIC1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-RNIC1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-RHIC1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-MNIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-MHIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-FNIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX-UTAV-FHIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. |
XNX-UTSV-NNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-NHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-RNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-RHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-MNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-MHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-FNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-FHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
SPARE MPD SENSORS |
MPD: Multi-Purpose Detector (mV) - ATEX |
MPD-AMCB1 XNX MPD ATEX/IEC SENSOR CAT 0-100%LEL |
MPD-AMIV1 XNX MPD ATEX/IEC SENSOR IR CH4 0-100%LEL |
MPD-AMIF1 XNX MPD ATEX/IEC SENSOR IR 0-100%LEL |
MPD-AMIC1 XNX MPD ATEX/IEC SENSOR IR CO2 0-5%VV |
MPD: Multi-Purpose Detector (mV) - UL/CSA |
MPD-UTCB1 XNX MPD UL/CSA SENSOR CAT 0-100%LEL |
MPD-UTIV1 XNX MPD UL/CSA SENSOR IR CH4 0-100%LEL |
MPD-UTIF1 XNX MPD UL/CSA SENSOR IR 0-100%LEL |
MPD-UTIC1 XNX MPD UL/CSA SENSOR IR CO2 0-5%VV |
SPARE MPD REPLACEABLE CARTRIDGES |
1226A0359 XNX MPD CAT CARTRIDGE 0-100%LEL |
1226-0300 XNX MPD IR CARTRIDGE 0-100%LEL |
1226-0301 XNX MPD IR CARTRIDGE CO2 0-5%VV |
1226-0299 XNX MPD IR CARTRIDGE CH4 0-100%LEL |